Registered Product Information
Manufacturer:
FLEXIM
Product Name:
Fluxus F704
Product Description:
Ultrasonic Flowmeter
Profile:
FOUNDATION Field Device
Date:
9/10/2014
More Information:
Ultrasonic clamp-on flow and concentration measurement
Non-invasive, ultrasonic flow measurement is only an outsider method in
the technical sense:
Clamp-on ultrasonic transducers are simply attached to the outside of the
pipe. The practical advantages are obvious: no wear and tear by the
medium, no risk of leakage, no pressure loss and, above all, constant
plant availability.
The fact that non-invasive measurement technology could prove itself as a
standard method in many areas of the industry, is, if nothing else, a
credit to FLEXIM. Berlins ultrasonic experts have repeatedly set new
standards with their FLUXUS® flowmeters. Staffs at FLEXIM are
particularly proud of the pioneering work carried out during the transfer
of ultrasonic technology to non-invasive flow measurement of gases.
FLEXIM is the only provider to carry out clamp-on ultrasonic flow
measurements in high temperatures of up to 400 °C.
FLUXUS F704
The FLUXUS® F704 meters are Flexims Ultrasonic measuring systems
for permanent installation in nearly any liquid and gas flow metering and
analysis application - especially in the industrial environment. Its
non-intrusive measurement technology ensures a precise bi-directional,
highly dynamic flow measurement over a wide turndown ratio.
Enclosed in a robust metal field housing, the Fluxus F704 meters are
completely water-tight and designed for usage in rough environments. As
the transducers are mounted on the outside of the pipe wall in rugged
VARIOFIX mounting fixtures, the system does not suffer from wear and tear
or clogging, can't be a risk for leaks and will not cause any pressure
drops inside the pipe.
Due to their matched and paired transducers as well as the internal
temperature compensation (compliant to ANSI/ASME regulations), the
measurement system is drift free and zero stable ensuring accurate
readings. Moreover, as the transducer calibration data is automatically
loaded by connecting the transducer to the transmitter the set-up times
are significantly reduced. As of its exceptional dual-uP technology, the
high number of measuring cycles per second and the adaptive signal
processing, the FLUXUS® F704 meters produce stable and reliable measuring
results even under the most difficult conditions.
* Non-intrusive liquid and gas flow and concentration metering -
Installation without process interruption or production stop
* Virtually maintenance free due to permanent coupling pads and rugged
mounting fixtures
* Low installation and operation costs (independent of pipe pressure
and size)
* Highly accurate, reliable and stable measuring results even under
difficult conditions
* Versatile electrical inputs and outputs for the optimal adaptation to
the individual application needs
* Ideal solution for the measurement of aggressive, corrosive or toxic
media in hazardous areas ( FM Class I, Div. II / ATEX (IECEx) Zone 2
version available)
* Exhaustive internal database with complete parameter set of a variety
pipe materials and media
* Ideal solution for permanent thermal energy / BTU metering
Volumetric and mass flow measurement at up to 400°C hot pipes by using
the patented WaveInjector Solution.
Registered Product Details
Manufacturer ID (hex):
464C58
Device Type ID (hex):
0046
DEV_REV (hex):
0x01
DD Revision:
0x01, 0x01(DD5)
FOUNDATION Physical Layer Profile:
113 - Standard-power signaling, bus-powered, non I.S.
115 - Standard-power signaling, bus-powered, energy limited (Ex nL)
Stack Manufacturer:
Softing AG
FOUNDATION Stack Class:
31PS, 32L
Stack Version:
2.42
Registered Blocks:
1-RB2(e), 8-AI(e), 1-DO(e),<br>1-PID(e)
Other Blocks:
1-AITB(c)
Registered Features:
Alarms and Events
Function Block Linking
Trending
Multi-bit Alert Reporting
Field Diagnostics
Registration Information
Registration Authority:
FieldComm Group
Registration Status:
Registered
Tester Version:
6.1.1
DD/CFF Tester Version:
6.1.1
Contact Information
Device Support File Usage
FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.