Manufacturer:
Mettler-Toledo GmbH
Product Name:
pH 2100e FF
Product Description:
pH Transmitter
Profile:
FOUNDATION Field Device
More Information:
The pH 2100e FF transmitter with FOUNDATION Fieldbus (FF) interface is an
enhancement of METTLER TOLEDOs successful «Advanced Line» transmitter
series. The transmitter is available as an intrinsically safe version for
operation in hazardous areas and is in accordance with the FISCO
(Fieldbus Intrinsically Safe Concept) model. Major areas of applications
are world-wide in the range of industrial applications from chemicals,
petrochemicals and pulp and paper to pharmaceuticals and food and
beverage.
Features and Benefits:
* Highly reliable and exact measurement
o Continuous remote diagnostic and Calimatic functions with
automated buffer recognition result in highest measurement
reliability.
* Calibration via the Fieldbus
o Freedom of choice - numerous calibration functions such as zero,
slope and product calibration can be performed via the fieldbus.
* Remote transmitter configuration
o The possibility of several remote configuration options grant
convenient transmitter configuration.
Specifications
* Measurement range pH: -2
16, mV: 1500
+ 1000
* Sensor inputs: pH, ORP (Redox), ISFET
* Temperature inputs: Pt100, Pt1000, NTC 30 kOhm, NTC 8,55 kOhm
* Approvals: ATEX, FM, IP 65, NEMA 4x
* Mounting options: Wall, panel, or pipe mounting
Manufacturer ID (hex):
465255
Device Type ID (hex):
0834
DEV_REV (hex):
01
DD Revision:
0x01
FOUNDATION Physical Layer Profile:
511 - Low-power signaling, bus-powered, FISCO I.S.
Stack Manufacturer:
Softing
FOUNDATION Stack Class:
31PS
Stack Version:
2.01
Registered Blocks:
3xAI(s), 1xRB(s)
Other Blocks:
1xTB(c)
Registered Features:
Alarms and Events
Function Block Linking
Trending
Registration Authority:
FieldComm Group
Registration Status:
Registered
Tester Version:
4.51
DD/CFF Tester Version:
4.6
FieldComm Group (FCG) makes available to its members and to the public certain device driver (DD) files, in various forms, that have passed certain tests conducted by or through FCG. The DD files are, or are created from, submissions to FCG by FCG members and are provided by FCG AS IS. FCG disclaims all liability for the accuracy, suitability or use of the DD files. Each member creating DD files has its own policies regarding supporting use of those files, and may, for instance support use of DD object code files, but not DeviceInfo or other files. While FCG is under no obligation to provide support for use of any DD files, FCG welcomes all inquiries on the subject and will often be able to assist.